Fabric CLI orientation
A no-incident calibration lab. Learn how UFM, DGX OS, Linux netdev names, and Cumulus NVUE each describe the same two-rail fabric before you start troubleshooting failures.
Labs
Each lab opens as a dedicated simulator session. Browse the available scenarios first, then enter the one you want to work on. ProDeploy labs are best experienced on desktop because they combine topology, multi-device CLI, and reference tooling in one workspace.
A no-incident calibration lab. Learn how UFM, DGX OS, Linux netdev names, and Cumulus NVUE each describe the same two-rail fabric before you start troubleshooting failures.
A healthy-link counter drill. Run a short RDMA write probe, then correlate switch-side PFC and RoCE counters with DGX ethtool counters so ECN marks, PFC pauses, and zero-drop behavior become familiar before incident labs.
A GPU rail has gone dark. Use the topology map and CLI tools to identify which rail, confirm the RDMA state, and isolate whether the fault is on the NIC or switch side.
A RoCEv2 workload is experiencing retransmissions. PFC is misconfigured. Diagnose and fix it.
Throughput has dropped 40%. Investigate using interface counters and ECN configuration commands.
AllReduce throughput has dropped with no drops visible. Diagnose why spine links are uneven and fix load balancing to restore full training throughput.
Two vendors propose different switch configurations for a 64-node DGX H100 cluster. Calculate oversubscription ratios, identify which proposal meets requirements, and submit a recommendation before the purchase order is signed.
A 16-node cluster shows 3 GB/s busbw instead of expected performance. All hardware is healthy. Diagnose why NCCL is using socket transport and fix the environment variable misconfiguration.
Training is 12% slower - but no hard errors anywhere. Use UFM port counters, DCGM GPU metrics, and switch counters to correlate a rising pre-FEC BER across three monitoring layers and identify the marginal physical connector before it becomes a full link failure.
A switch looks healthy at a glance, but the NIC reveals a severe pause storm. Check both ends, identify missing ECN, and restore rate control before continuous PFC pauses collapse throughput.
PFC is enabled, but on the wrong traffic class. Cross-check NIC drops, PFC priority output, and RoCE DSCP-to-priority mapping, then move PFC protection back to priority 3.
A rail has gone err-disabled after a physical fault. Recognise the NIC-side active-state trap, confirm the switch port failure, replace the optic, clear err-disable, and verify full recovery.
A reduced-capacity spine is still receiving equal ECMP traffic. Identify the missing BGP Link Bandwidth community and restore weighted ECMP before PFC storms spread.
A link failure triggers a bad 3-hop path because the spines use different ASNs. Trace the suboptimal route, unify the spine ASN design, and verify clean failover behavior.
Steer checkpoint-to-storage traffic onto a dedicated SRv6-TE path so collective traffic keeps the uncongested spine pool.
Reproduce an RDMA RKEY exposure attack from a multi-tenant cluster, identify the two misconfigurations that enabled it, and apply GID filtering and RKEY rotation to harden the environment.
Audit a newly racked Spectrum-X scalable unit before RoCE configuration begins by verifying version, ports, ASIC identity, MTU baseline, and BGP cleanliness.
Apply the Day-0 Spectrum-X RoCE QoS profile, verify DSCP trust and PFC/ECN state, and validate the fabric with ib_write_bw and ib_write_lat.
Diagnose a broken ECN profile, compare thresholds to the carved lossless buffer, then restore DCQCN marking under multi-flow load.
Fix a Spectrum-X fabric where per-packet AR silently fell back to a broken per-flowlet setup because BF3 reorder buffers were never enabled on the DGX B200 hosts.
Diagnose and fix a BGP-EVPN route-target misconfiguration that leaks TenantA's storage routes into TenantB's VRF.